Thermal Cameras
A10
A20
A40
B2
B4
E25
E45
E65
E320
Infrared Applications
Thermal Survey
Thermal Images
Contact Details
-
Affordable, Fully Integrated Thermal Measurement
Solution
-
Field of view / min focus distance 24°x18° /0.3 m
(with 35 mm lens)
-
Spatial resolution (IFOV) 1.3 mrad
-
Thermal sensitivity 0.08°C at 30°C
-
Focusing Built-in focus motor. Manual or automatic
focus
-
Detector type Focal Plane Array (FPA), uncooled
microbolometer (320 x 240 pixels)
-
Spectral range 7.5 to 13 µm
-
Image frequency 50/60 Hz
-
Viewing temperature range -40°C to +500°C (-40°F to
+932°F), in 2 ranges Optional: Up to +1500°C (2732°F) or +2000°C (3632°F)
|
ThermoVision - A40 -
Compact Infrared Camera for Research and Development
|
Camera Features
Technical Specification
Download A40-M Brochure
Download A40-V Brochure
Typical Application for the A40
The use of thermal imaging cameras in scientific research is wide and varied. Uses range from the study of leaf development in plants through to research in the pharmaceutical industry. The emphasis for infrared cameras in this area is on providing accuracy and functionality and the ability to provide repeatable results. PC connectivity is also important for both remote operation and analysis of results.
|
|
Infrared vision systems are used worldwide in a
variety of industries to monitor continuous
processes. Infrared can easily detect thermal
information on product quality and/or production
efficiency that is difficult or impossible to
capture using conventional means such as
thermocouples or visible light cameras. The
ThermoVision A40 is an affordable and accurate
temperature measurement system. It is the ideal
choice for industrial and automation applications
requiring accurate non contact temperature
measurement.
ThermoVision A40 Features
|
Precision Non-Contact Temperature Measurement And Excellent Image
Quality
The ThermoVision A40-M allows you to see
temperature differences as small as 0.08°C in a range from -40°C up to
+500°C (up to 2,000°C optional). It produces crisp high resolution
images (320 x 240 pixels) offering more than 76,800 individual
measurement points per image at a refresh rate of 50/60 Hz.
Input / Output Functionality
Fully configured I/O functionality
allows the A40-M either to be integrated quickly and easily in your
control systems or to be set up as a stand-alone system. The operator
can set and modify up to 4 areas in the camera’s field of view. If, for
example, the temperature within one of these areas rises above or falls
below a predefined value, an alarm will go off.
Multiple Programming Options
The A40-M calibrated measurement output
can be easily used to control a process. No need for months of
programming. For application developers FLIR Systems offers two software
components. A ThermoVision SDK-kit for Visual Basic / C++ programmers
and a ThermoVision LabView™ Toolkit for those familiar with National
Instruments LabView. Both software kits are based on ActiveX technology.
Ultra Compact, Rugged And Lightweight
Its compact and ultra-light design
allows the A40-M to be mounted in hard-to-get-at locations in your
production line. |
|
Extensive Connectivity Options: Firewire Or Ethernet
The A40-M features a choice of
connectivity options. For real-time image and fast data transfer of
fully radiometric 16-bit images, you can choose for an IEEE-1394
FireWire digital output. For network and/or multiple camera
installations, Ethernet connectivity is available. Each A40-M can be
equipped with its own unique URL allowing it to be addressed
independently via its Ethernet connection. It allows controlling all
menu systems of the camera and provides instant access to A40-M thermal
images for any authorized user with a web browser. Images are streamed
in semi real-time.
Integrated Keyboard
For those applications where the
infrared camera and the PC are a distance away from each other, the
ThermoVision A40-M has an integrated keyboard. With a few buttons,
conveniently placed at the top of the camera, you can control all
features.
Easy Operation: Plug And Play
Simply connect the camera to a PC or a
monitor and produce high-quality real-time radiometric images. The
camera can be fully controlled either from the PC or with the integrated
keyboard. |
Technical Specification for the A40 ThermoVision
|
Imaging Performance
|
|
Thermal sensitivity
Field of View / Min Focus distance
Spatial Resolution (IFOV)
Built-in Focus Motor
Detector type
Spectral range
Image Frequency
Viewing Temperature Range
Optional |
0.80°C at 30°C
24° x 18°/0.3m (with 35mm Lens)
1.3 mrad
Manual or automatic
Focal
Plane Array (FPA), uncooled microbolometer (320 x 240 pixels)
7.5
to 13 µm
50/60 Hz
-40°C to +500°C (-40°F to +932°F) in 2
ranges
Up to +1500°C (2732°F) or +2000°C (3632°F)
|
Image Presentation
|
|
Image output |
RS170 EIA/NTSC or CCIR/PAL analogue composite
video and FireWire (IEEE-1394) 8-bit digital image output or
Ethernet 8-bit digital output (RTP) |
Measurement
|
|
Temperature ranges
Accuracy
Measurement modes
Emissivity corrections
Reflected ambient temperature correction
External optics / window correction |
-40°C to +500°C (-40°F to +932°F) in 2 ranges,
Optional: Up to +1,500°C (2,732°F), or +2,000°C (3,632°F)± 2°C, ± 2% of reading
± 2°C, ± 2% of reading
Spot (up to 6), area (4), isotherm, Delta T,
iso-coverage
Variable from 0.1 to 1.0
Automatic, based on input of reflected
temperature
Automatic, based on input of optics/window
transmission and temperature |
Lenses (Optional)
|
|
Field of view / min. focus distance
Lens identification |
7° x 5.3°/4 m (with 122 mm lens)
12° x 9°/1.2 m (with 71 mm lens)
45° x 34°/0.1 m (with 18 mm lens)
80° x 60°/0.1 m (with 9 mm lens)
200 µm close-up (64 mm x 48 mm/150 mm)
100 µm close-up (34 mm x 25 mm/80 mm)
50 µm close-up (15 mm x 11 mm/19 mm)
18 µm close-up (6 mm x 4 mm/7 mm)
Automatic |
Power Source
|
|
AC Operation
Voltage
|
AC Adaptor 110/220 VAC, 50/60Hz
10/30 V nominal, <6W |
Environmental Specification
|
|
Operating temperature range
Storage temperature range
Humidity
Encapsulation
Shock
Vibration |
-15°C to +55°C (+5°F to +122°F)
-40°C to +70°C (-40°F to +158°F)
Operating and storage 10% to 95%, non condensing
IP 40 (determined by connector type)
Operational: 25G, IEC 68-2-29
Operational: 2G, IEC 68-2-6 |
Physical Characteristics |
|
Weight
Size
Tripod Mounting |
1.4kg, (3.1lbs)
207 mm x 92 mm x 109 mm
1/4" - 20 |
Interfaces
|
|
Digital image output & camera control
BNC
6-pin screw terminal (upper)
6-pin screw terminal (lower) |
6-pin FireWire (IEEE-1394) connector handling
iso-chronous and camera control, 8-bit digital image data and asynchronous
control data or standard RJ-45 Ethernet connector handling image data (RTP)
and
control data (TCP/IP)
Composite video (NTSC/PAL)
Digital I/O: 3 Output - 1 Input, 1 Input/Output selectable. User
configurable*
Analogue I/O: 2 Output - 1 Input, User
configurable* - see user configuration table |
User Configuration Table*
|
|
Type |
Function |
Remark |
|
Digital input |
TTL Level: Shutter disable, Store image, Batch enable |
Isolation and relay function in external module |
|
Digital output |
TTL Level: Spot / Area threshold alarm, Internal temperature sensor
alarm,
V-sync |
Isolation and relay function in external module |
|
Analogue output |
Spot / Area out 0 - 5 V,
Internal temperature sensor out 0 - 5 V |
Scaled to Tlow - Thigh
Isolation in external module |
|
Analogue input |
External temperature sensor in 0 - 10 V |
Scaled to Tlow - Thigh
Isolation in external module |
ThermoVision A40 includes
|
|
IR Camera, Power Supply including Cable Firewire Cable - (Firewire
Version Only), Configuration CD, Lens Cap, Manual
|
|
|